Product Description:
J&D Manufacturing’s 24" and 36" Panel Fans have a rugged x-frame mount with an efficient motor and a powerful balanced blade that is designed to create comfortable air velocity. The cushion-mounted maintenance-free bearings and heavy-duty automatic belt tensioning device on belted models make this fan one of the highest performing, lowest maintenance, greatest valued fans on the market!

INTERESTED IN THIS PRODUCT?

Fill out the form and we will be in touch within a business day!

  • Have a question about this product?
  • Complete the form below and we'll be in touch with you soon.

READY TO PURCHASE?

Find a Dealer

Key Features:

  • 36” belt drive models include a heavy-duty spring belt tensioner
  • 24” models have a rigid guard motor mount
  • Pole mounted fans or suspend with chains from the ceiling
  • Shaft bearings are eccentric locking, pre-lubricated, permanently sealed and rubber mounted for smooth operation and reduced blade fatigue, and are covered by a 3 Year Warranty
  • Totally enclosed, maintenance-free, high-efficiency motors have completely sealed ball bearings,  are UL and CUL recognized, and are covered by a 2 Year Warranty
  • Gold Star Motors are covered by a 3 Year Warranty
  • 36″ available in belt drive and direct drive models

Applications:

  • Dairy
  • Industrial
Part # Motor Wiring Instructions Size Output (CFM) HP Volts Amps NP Hz Ph Spd RPM Drive Prop Test # Cord Speed Control Compatible VFD Compatible Fixed or Portable Oscillating FPM Thrust CFM Thrust (lbf) Thrust Eff. Ratio kW Thrust CFM/ Watt
Part - Motor Wiring Instructions Size Output (CFM) HP Volts Amps NP Hz Ph Spd RPM Drive Prop Test # Cord Speed Control Compatible VFD Compatible Fixed or Portable Oscillating FPM Thrust CFM Thrust (lbf) Thrust Eff. Ratio kW Thrust CFM/ Watt
Gold Star Single Phase
VP36D-GS --- 36" 10,710 1/2 115/230 6.1/3.09 60 1 1 859 Direct 3-Glv C22007 No No No Fixed Non 960 10,840 10.4 19.3 0.54 20.1
Gold Star Three Phase
VP243G-GS --- 24” 10,470 1/2 230/460 2.6/1.3 60 3 1 851 Direct 3-Glv C22009 No Yes, w/VFD Yes Fixed Non 1,040 5,780 6.7 15.7 0.427 13.5
VP363D-GS --- 36" 10,590 1/2 230/460 2.6/1.3 60 3 1 853 Direct 3-Glv C19341 No Yes No Fixed Non 790 10,590 9.8 21.0 0.47 22.7
Single Phase
VP24 --- 24” 5,450 1/2 115/230 4.8/2.4 60 1 1 1,701 Direct 3-Alm C16428 No Yes No Fixed Non 1,320 5,450 5.85 16.5 0.35 15.4
VP36D --- 36" 10,600 1/2 115/230 6.1/3.09 60 1 1 854 Direct 3-Glv C18002 No Yes No Fixed Non 980 10,600 10.2 19.6 0.52 20.4
VP36 --- 36" 11,030 1/2 115/230 6.6/3.3 60 1 1 579 Belt 4-Glv C08009 No Yes No Fixed Non 790 11,030 10.4 18.4 0.57 19.4
VP361 --- 36” 13,000 1 115/208-230 9.0/4.5 60 1 1 680 Belt 4-Glv C18008 No No No Fixed Non 1,020 13,000 15.4 19.2 0.80 16.3
Three Phase
VP243G --- 24" 5,740 1/2 230/460 2.6/1.3 60 3 1 859 Direct 3-Glv C19338 No Yes Yes Fixed Non 1,150 5,740 6.4 15.0 0.43 13.4
VP363D --- 36” 10,470 1/2 230/460 2.6/1.3 60 3 1 856 Direct 3-Glv C18012 No Yes Yes Fixed Non 860 10,470 10.1 21.5 0.47 22.3
Part #
VP36D-GS
Gold Star Single Phase
Details
Panel Fan, 36" DD 115/230V 1/2HP 1PH, 1/Var, GS Motor, 3Galv
Motor Wiring Instructions
---
Size
36"
Output (CFM)
10,710
HP
1/2
Volts
115/230
Amps NP
6.1/3.09
Hz
60
Ph
1
Spd
1
RPM
859
Drive
Direct
Prop
3-Glv
Test #
C22007
Cord
No
Speed Control Compatible
No
VFD Compatible
No
Fixed or Portable
Fixed
Oscillating
Non
FPM
960
Thrust CFM
10,840
Thrust (lbf)
10.4
Thrust Eff. Ratio
19.3
kW
0.54
Thrust CFM/ Watt
20.1
Part #
VP243G-GS
Gold Star Three Phase
Details
Panel Fan, 24" DD 230/460V 1/2HP 3PH, 1/Var GS, 3 Galv Blade
Motor Wiring Instructions
---
Size
24”
Output (CFM)
10,470
HP
1/2
Volts
230/460
Amps NP
2.6/1.3
Hz
60
Ph
3
Spd
1
RPM
851
Drive
Direct
Prop
3-Glv
Test #
C22009
Cord
No
Speed Control Compatible
Yes, w/VFD
VFD Compatible
Yes
Fixed or Portable
Fixed
Oscillating
Non
FPM
1,040
Thrust CFM
5,780
Thrust (lbf)
6.7
Thrust Eff. Ratio
15.7
kW
0.427
Thrust CFM/ Watt
13.5
Part #
VP363D-GS
Gold Star Three Phase
Details
Panel Fan, 36" DD 115/230V 1/2HP 1PH, 1/Var, GS Motor, 3Galv
Motor Wiring Instructions
---
Size
36"
Output (CFM)
10,590
HP
1/2
Volts
230/460
Amps NP
2.6/1.3
Hz
60
Ph
3
Spd
1
RPM
853
Drive
Direct
Prop
3-Glv
Test #
C19341
Cord
No
Speed Control Compatible
Yes
VFD Compatible
No
Fixed or Portable
Fixed
Oscillating
Non
FPM
790
Thrust CFM
10,590
Thrust (lbf)
9.8
Thrust Eff. Ratio
21.0
kW
0.47
Thrust CFM/ Watt
22.7
Part #
VP24
Single Phase
Details
Panel Fan, 24" DD 115/230V 1/2HP 1PH 3 Aluminum Blade
Motor Wiring Instructions
---
Size
24”
Output (CFM)
5,450
HP
1/2
Volts
115/230
Amps NP
4.8/2.4
Hz
60
Ph
1
Spd
1
RPM
1,701
Drive
Direct
Prop
3-Alm
Test #
C16428
Cord
No
Speed Control Compatible
Yes
VFD Compatible
No
Fixed or Portable
Fixed
Oscillating
Non
FPM
1,320
Thrust CFM
5,450
Thrust (lbf)
5.85
Thrust Eff. Ratio
16.5
kW
0.35
Thrust CFM/ Watt
15.4
Part #
VP36D
Single Phase
Details
Panel Fan, 36" DD 115/230V 1/2HP 1PH 3 Galv Blade
Motor Wiring Instructions
---
Size
36"
Output (CFM)
10,600
HP
1/2
Volts
115/230
Amps NP
6.1/3.09
Hz
60
Ph
1
Spd
1
RPM
854
Drive
Direct
Prop
3-Glv
Test #
C18002
Cord
No
Speed Control Compatible
Yes
VFD Compatible
No
Fixed or Portable
Fixed
Oscillating
Non
FPM
980
Thrust CFM
10,600
Thrust (lbf)
10.2
Thrust Eff. Ratio
19.6
kW
0.52
Thrust CFM/ Watt
20.4
Part #
VP36
Single Phase
Details
Panel Fan, 36" BD 115/230V 1/2HP 1PH 4 Galv Blade
Motor Wiring Instructions
---
Size
36"
Output (CFM)
11,030
HP
1/2
Volts
115/230
Amps NP
6.6/3.3
Hz
60
Ph
1
Spd
1
RPM
579
Drive
Belt
Prop
4-Glv
Test #
C08009
Cord
No
Speed Control Compatible
Yes
VFD Compatible
No
Fixed or Portable
Fixed
Oscillating
Non
FPM
790
Thrust CFM
11,030
Thrust (lbf)
10.4
Thrust Eff. Ratio
18.4
kW
0.57
Thrust CFM/ Watt
19.4
Part #
VP361
Single Phase
Details
Panel Fan, 36" BD 115/230V 1HP 1PH 4 Galv Blade
Motor Wiring Instructions
---
Size
36”
Output (CFM)
13,000
HP
1
Volts
115/208-230
Amps NP
9.0/4.5
Hz
60
Ph
1
Spd
1
RPM
680
Drive
Belt
Prop
4-Glv
Test #
C18008
Cord
No
Speed Control Compatible
No
VFD Compatible
No
Fixed or Portable
Fixed
Oscillating
Non
FPM
1,020
Thrust CFM
13,000
Thrust (lbf)
15.4
Thrust Eff. Ratio
19.2
kW
0.80
Thrust CFM/ Watt
16.3
Part #
VP243G
Three Phase
Details
Panel Fan, 24" DD 230/460V 1/2HP 3PH 3 Galv Blade
Motor Wiring Instructions
---
Size
24"
Output (CFM)
5,740
HP
1/2
Volts
230/460
Amps NP
2.6/1.3
Hz
60
Ph
3
Spd
1
RPM
859
Drive
Direct
Prop
3-Glv
Test #
C19338
Cord
No
Speed Control Compatible
Yes
VFD Compatible
Yes
Fixed or Portable
Fixed
Oscillating
Non
FPM
1,150
Thrust CFM
5,740
Thrust (lbf)
6.4
Thrust Eff. Ratio
15.0
kW
0.43
Thrust CFM/ Watt
13.4
Part #
VP363D
Three Phase
Details
Panel Fan, 36" DD 230/460V 1/2HP 3PH 3 Galv Blade
Motor Wiring Instructions
---
Size
36”
Output (CFM)
10,470
HP
1/2
Volts
230/460
Amps NP
2.6/1.3
Hz
60
Ph
3
Spd
1
RPM
856
Drive
Direct
Prop
3-Glv
Test #
C18012
Cord
No
Speed Control Compatible
Yes
VFD Compatible
Yes
Fixed or Portable
Fixed
Oscillating
Non
FPM
860
Thrust CFM
10,470
Thrust (lbf)
10.1
Thrust Eff. Ratio
21.5
kW
0.47
Thrust CFM/ Watt
22.3

Product Details:

Part #

Motor Wiring Instructions

Size

HP

Volts

Amps NP

Hz

Phase

Speed

RPM

Drive

Prop

Test #

Speed Control Compatibility

VFD Compatible

Fixed or Portable

FPM

Thrust CFM

Thrust (lbf)

Thrust Eff. Ratio

kW

Thrust CFM/ Watt

Gold Star Single Phase

VP36D-GS

---

36"

1/2

115/230

6.1/3.09

60

1

1

859

Direct

3-Glv

C22007

No

No

Fixed

960

10.4

19.3

0.54

20.1

Gold Star Three Phase

VP243G-GS

---

24”

1/2

230/460

2.6/1.3

60

3

1

851

Direct

3-Glv

C22009

Yes, w/VFD

Yes

Fixed

1,040

6.7

15.7

0.427

13.5

Gold Star Three Phase

VP363D-GS

---

36"

1/2

230/460

2.6/1.3

60

3

1

853

Direct

3-Glv

C19341

Yes

No

Fixed

790

9.8

21.0

0.47

22.7

Single Phase

VP24

---

24”

1/2

115/230

4.8/2.4

60

1

1

1,701

Direct

3-Alm

C16428

Yes

No

Fixed

1,320

5.85

16.5

0.35

15.4

Single Phase

VP36D

---

36"

1/2

115/230

6.1/3.09

60

1

1

854

Direct

3-Glv

C18002

Yes

No

Fixed

980

10.2

19.6

0.52

20.4

Single Phase

VP36

---

36"

1/2

115/230

6.6/3.3

60

1

1

579

Belt

4-Glv

C08009

Yes

No

Fixed

790

10.4

18.4

0.57

19.4

Single Phase

VP361

---

36”

1

115/208-230

9.0/4.5

60

1

1

680

Belt

4-Glv

C18008

No

No

Fixed

1,020

15.4

19.2

0.80

16.3

Three Phase

VP243G

---

24"

1/2

230/460

2.6/1.3

60

3

1

859

Direct

3-Glv

C19338

Yes

Yes

Fixed

1,150

6.4

15.0

0.43

13.4

Three Phase

VP363D

---

36”

1/2

230/460

2.6/1.3

60

3

1

856

Direct

3-Glv

C18012

Yes

Yes

Fixed

860

10.1

21.5

0.47

22.3

Product Details:

Part #

Motor Wiring Instructions

Size

HP

Volts

Amps NP

Hz

Phase

Speed

RPM

Drive

Prop

Test #

Speed Control Compatibility

VFD Compatible

Fixed or Portable

FPM

Thrust CFM

Thrust (lbf)

Thrust Eff. Ratio

kW

Thrust CFM/ Watt

Housing Material

Housing Color

Guard material & coating

Guard Color

Blade Material

Blade Color

Gold Star Single Phase

VP36D-GS

---

36"

1/2

115/230

6.1/3.09

60

1

1

859

Direct

3-Glv

C22007

No

No

Fixed

960

10,840

10.4

19.3

0.54

20.1

Galvanized

Metallic

Galvanized

Metallic

Gold Star Three Phase

VP243G-GS

---

24”

1/2

230/460

2.6/1.3

60

3

1

851

Direct

3-Glv

C22009

Yes, w/VFD

Yes

Fixed

1,040

5,780

6.7

15.7

0.427

13.5

Galvanized

Metallic

Galvanized

Metallic

Gold Star Three Phase

VP363D-GS

---

36"

1/2

230/460

2.6/1.3

60

3

1

853

Direct

3-Glv

C19341

Yes

No

Fixed

790

10,590

9.8

21.0

0.47

22.7

Galvanized

Metallic

Galvanized

Metallic

Single Phase

VP24

---

24”

1/2

115/230

4.8/2.4

60

1

1

1,701

Direct

3-Alm

C16428

Yes

No

Fixed

1,320

5,450

5.85

16.5

0.35

15.4

Galvanized

Metallic

Alum

Metallic

Single Phase

VP36D

---

36"

1/2

115/230

6.1/3.09

60

1

1

854

Direct

3-Glv

C18002

Yes

No

Fixed

980

10,600

10.2

19.6

0.52

20.4

Galvanized

Metallic

Galvanized

Metallic

Single Phase

VP36

---

36"

1/2

115/230

6.6/3.3

60

1

1

579

Belt

4-Glv

C08009

Yes

No

Fixed

790

11,030

10.4

18.4

0.57

19.4

Galvanized

Metallic

Galvanized

Metallic

Single Phase

VP361

---

36”

1

115/208-230

9.0/4.5

60

1

1

680

Belt

4-Glv

C18008

No

No

Fixed

1,020

13,000

15.4

19.2

0.80

16.3

Galvanized

Metallic

Galvanized

Metallic

Three Phase

VP243G

---

24"

1/2

230/460

2.6/1.3

60

3

1

859

Direct

3-Glv

C19338

Yes

Yes

Fixed

1,150

5,740

6.4

15.0

0.43

13.4

Galvanized

Metallic

Galvanized

Metallic

Three Phase

VP363D

---

36”

1/2

230/460

2.6/1.3

60

3

1

856

Direct

3-Glv

C18012

Yes

Yes

Fixed

860

10,470

10.1

21.5

0.47

22.3

Galvanized

Metallic

Galvanized

Metallic

FAQs:

Ventilation helps to maintain a healthy environment by regulating moisture and humidity, controlling temperatures, removing fumes and odors, and exchanging fresh air for humans and animals to maximize productivity.
Heat stress in animals is a very serious condition that can lead to a decrease in appetite, loss of milk or egg production, shutdown of the reproduction system, diminished nutrient absorption, poor growth and even death in extreme cases.
There are many important factors to consider when purchasing a fan. Besides cost, you should also consider the efficiency of the fan, the noise level, and the energy use. Many ventilation fans have a lower upfront price tag, but will cost you more over time by consuming large amounts of energy.
J&D has numerous options for your dairy ventilation system including natural, recirculation, tunnel, and cross-tunnel ventilation. In addition to these basic ventilation types, evaporative pad cooling, soaking, misting, fogging and mechanical ventilation can all be intermixed to maximize the cooling capacity of your system.
A Natural Ventilation System relies only on wind to cool your barn using open side walls or curtain side walls.

Advantages: low investment cost, low electrical operating cost, zero fan noise, easy management and operation, bright and airy work space, animals will not be affected by power failures.

Disadvantages: little to no temperature and air exchange control, no insect control, radiant sun increases temperature on outside stalls, precise building location is required to maximize wind direction.
A Tunnel Ventilation System uses a series of exhaust fans on the short end of your building with inlets located on the opposite end. Air enters the building through the inlets where it is pulled down the length of your building like a wind tunnel and exhausted out the opposite end. The exhaust fans create air exchange and a high velocity air movement.

Advantages: insect control, consistent environment, proper temperature, humidity and odor control, keeps bedding and floors dry.

Disadvantages: higher investment cost when compared to natural ventilation, very little natural light, not suitable for year round use without a fresh air system due to inadequate fresh air distribution during cool winter ventilation conditions.
Cross Tunnel Ventilation is very similar to Tunnel Ventilation whereas a series of exhaust fans and inlets are used on the walls of your building. With Cross Tunnel Ventilation, the exhaust fans and inlets are located on the long sides of your building instead of the short sides. The air is pulled through the width of your building instead of through the length like it is with regular Tunnel Ventilation.

Advantages: building ends can be used for necessary overhead doors, insect control, consistent environment, proper temperature, humidity and odor control, keeps bedding and floors dry.

Disadvantages: higher investment cost when compared to natural ventilation, very little natural light, not suitable for year round use due to inadequate fresh air distribution during cool winter ventilation conditions.
Recirculation Ventilation uses a series of recirculation fans that are positioned to blow air across the animals to create a cooling effect. When designed properly with an open or curtain side wall, you can also get an air exchange in the building.

Advantages: insect control, consistent environment, proper temperature, humidity and odor control, keeps bedding and floors dry

Disadvantages: higher installation and operating costs when compared to natural ventilation.
Selecting a ventilation system depends on a number of factors including budget, building location and orientation, and your complete ventilation strategy. Call our ventilation experts at 1-800-998-2398 or e-mail us at jdmfg@jdmfg.com to help design the best system for you.
J&D has knowledgable Engineering and Sales staff that can assist you in this process. We will design and recommend options to give you the most effective system. Call our ventilation experts at 1-800-998-2398 or e-mail us at jdmfg@jdmfg.com to help design the best system for you.
All fans should be cleaned regularly by removing accumulated dirt and debris on louvers, blades and motors to improve performance. Dirt that clogs your fan motor will cause it to run hot, and will reduce the life of your motor. You should also regularly check fan belts and keep them adjusted to factory specifications. Loose belts can cause belt slippage and will reduce the airflow of your fan.
J&D recommends a cooling system when temperatures reach between 85° – 90° depending on your application.
In the summer, a ceiling fan creates a mild wind chill to help cool the building. In the winter, a ceiling fan helps to mix the warm air that collects on the ceiling and in the peaks of most industrial and commercial buildings. By installing a ceiling fan, the warm air is recirculated back down to the floor level to help maintain a uniform temperature and save on heating costs.
For preventing heat stratification, it will be depend on the height of the ceiling. With ceilings between 15′ and 30′, ceiling fans should be mounted to cover 4000 square feet of floor area. For cooling people during the hot summer months, fans should be placed 15′ to 20′ apart.
J&D recommends having all electrical work performed by a certified electrician. The electrician can find the wiring diagram on the motor label.
J&D offers a 2 year replacement warranty on all electric fan motors, unlike many of our competitors who offer only a one year warranty. Warranty is based on invoice date to the dealer, J&D does not cover freight or labor. POW14, POW18, POW18B, POW24OSC, POW30OSC, VBM60PSC-P, VBM148PSC-P, PDF24, and VRSM10-Power inlet motor carry a 1 year warranty. VR3E and VR33 motors (Mega Storm Fan) carry a 3 year warranty.