Product Description:
The JD360 is an effective destratification fan that mixes the heavy, cool, dense air that is sunk to ground level with the warm, light, thin air that lingers towards the top of your facility. This provides a comfortable and uniform healthy environment from the top of the peaks to the ground of your house. It's the perfect vertical, low-airspeed circulator and it’s paired with J&D’s impressive IP66-rated Gold Star Motor that is covered by a 3 year warranty. It’s easy to install and maintenance-free. Save money on your labor and your heating bill with the JD360. You’ll like the price and the pallet quantity discount!

INTERESTED IN THIS PRODUCT?

Fill out the form and we will be in touch within a business day!

  • Have a question about this product?
  • Complete the form below and we'll be in touch with you soon.

READY TO PURCHASE?

Find a Dealer

Key Features:

  • Priced 25% Less than the competition
  • Reduce the temperature gradient from floor to ceiling by up to 55%
  • Enhance cooling power and control humidity levels with high pressure fog attachment

 

Reduces:
  • Temp stratification and dead zones
  • Moisture condensation
  • Electric bills

 

Provides:
  • Even mixing of air
  • Healthier, more comfortable environment

 

Includes:
  • IP66-rated Gold Star Motor
  • 3 year warranty on the ENTIRE fan!

 

Applications:

  • Greenhouse
  • Industrial
  • Poultry
Part # Size Output (CFM) HP Volts Amps NP Hz Ph Spd RPM Drive Prop Test # Cord Speed Control Compatible VFD Compatible Fixed or Portable Oscillating FPM Thrust CFM Thrust (lbf) Thrust Eff. Ratio kW Thrust CFM/ Watt
Part - Size Output (CFM) HP Volts Amps NP Hz Ph Spd RPM Drive Prop Test # Cord Speed Control Compatible VFD Compatible Fixed or Portable Oscillating FPM Thrust CFM Thrust (lbf) Thrust Eff. Ratio kW Thrust CFM/ Watt
Single Phase
JD360 18" 1/4 115/230 3.9/1.95 60 1 1 Direct 6-PLY fixed No 1,790
Part #
JD360
Single Phase
Details
JD360 Destratification Fan, 18", White
Size
18"
Output (CFM)
HP
1/4
Volts
115/230
Amps NP
3.9/1.95
Hz
60
Ph
1
Spd
1
RPM
Drive
Direct
Prop
6-PLY
Test #
Cord
Speed Control Compatible
VFD Compatible
Fixed or Portable
fixed
Oscillating
No
FPM
1,790
Thrust CFM
Thrust (lbf)
Thrust Eff. Ratio
kW
Thrust CFM/ Watt

Product Details:

Part #

Size

HP

Volts

Amps NP

Hz

Phase

Speed

RPM

Drive

Prop

Test #

Speed Control Compatibility

VFD Compatible

Fixed or Portable

FPM

Thrust CFM

Thrust (lbf)

Thrust Eff. Ratio

kW

Thrust CFM/ Watt

Single Phase

JD360

18"

1/4

115/230

3.9/1.95

60

1

1

Direct

6-PLY

fixed

1,790

Product Details:

Part #

Size

HP

Volts

Amps NP

Hz

Phase

Speed

RPM

Drive

Prop

Test #

Speed Control Compatibility

VFD Compatible

Fixed or Portable

FPM

Thrust CFM

Thrust (lbf)

Thrust Eff. Ratio

kW

Thrust CFM/ Watt

Housing Material

Housing Color

Guard material & coating

Guard Color

Blade Material

Blade Color

Single Phase

JD360

18"

1/4

115/230

3.9/1.95

60

1

1

Direct

6-PLY

fixed

1,790

poly

white

Heavy Gauge Steel, Powder coated - corrosion resistant

White

poly

white

Accessories:

Part # Details
Optional Mounting Brackets
HK222 Mounting Bracket for 2” OD Round Pipe
HK223 Mounting Bracket for 2” OD Square Pipe
HPF Ring Kits
SS2218 JD360 Fog Ring Kit, 22” with (8).006 GPM Nozzles = .048 GPM
SS2228 JD360 Fog Ring Kit, 22” with (8).015 GPM Nozzles = .120 GPM
SS2238 JD360 Fog Ring Kit, 22” with (8).039 GPM Nozzles = .312 GPM

FAQs:

Ventilation helps to maintain a healthy environment by regulating moisture and humidity, controlling temperatures, removing fumes and odors, and exchanging fresh air for humans and animals to maximize productivity.
Heat stress in animals is a very serious condition that can lead to a decrease in appetite, loss of milk or egg production, shutdown of the reproduction system, diminished nutrient absorption, poor growth and even death in extreme cases.
There are many important factors to consider when purchasing a fan. Besides cost, you should also consider the efficiency of the fan, the noise level, and the energy use. Many ventilation fans have a lower upfront price tag, but will cost you more over time by consuming large amounts of energy.
J&D has numerous options for your dairy ventilation system including natural, recirculation, tunnel, and cross-tunnel ventilation. In addition to these basic ventilation types, evaporative pad cooling, soaking, misting, fogging and mechanical ventilation can all be intermixed to maximize the cooling capacity of your system.
A Natural Ventilation System relies only on wind to cool your barn using open side walls or curtain side walls.

Advantages: low investment cost, low electrical operating cost, zero fan noise, easy management and operation, bright and airy work space, animals will not be affected by power failures.

Disadvantages: little to no temperature and air exchange control, no insect control, radiant sun increases temperature on outside stalls, precise building location is required to maximize wind direction.
A Tunnel Ventilation System uses a series of exhaust fans on the short end of your building with inlets located on the opposite end. Air enters the building through the inlets where it is pulled down the length of your building like a wind tunnel and exhausted out the opposite end. The exhaust fans create air exchange and a high velocity air movement.

Advantages: insect control, consistent environment, proper temperature, humidity and odor control, keeps bedding and floors dry.

Disadvantages: higher investment cost when compared to natural ventilation, very little natural light, not suitable for year round use without a fresh air system due to inadequate fresh air distribution during cool winter ventilation conditions.
Cross Tunnel Ventilation is very similar to Tunnel Ventilation whereas a series of exhaust fans and inlets are used on the walls of your building. With Cross Tunnel Ventilation, the exhaust fans and inlets are located on the long sides of your building instead of the short sides. The air is pulled through the width of your building instead of through the length like it is with regular Tunnel Ventilation.

Advantages: building ends can be used for necessary overhead doors, insect control, consistent environment, proper temperature, humidity and odor control, keeps bedding and floors dry.

Disadvantages: higher investment cost when compared to natural ventilation, very little natural light, not suitable for year round use due to inadequate fresh air distribution during cool winter ventilation conditions.
Recirculation Ventilation uses a series of recirculation fans that are positioned to blow air across the animals to create a cooling effect. When designed properly with an open or curtain side wall, you can also get an air exchange in the building.

Advantages: insect control, consistent environment, proper temperature, humidity and odor control, keeps bedding and floors dry

Disadvantages: higher installation and operating costs when compared to natural ventilation.
Selecting a ventilation system depends on a number of factors including budget, building location and orientation, and your complete ventilation strategy. Call our ventilation experts at 1-800-998-2398 or e-mail us at jdmfg@jdmfg.com to help design the best system for you.
J&D has knowledgable Engineering and Sales staff that can assist you in this process. We will design and recommend options to give you the most effective system. Call our ventilation experts at 1-800-998-2398 or e-mail us at jdmfg@jdmfg.com to help design the best system for you.
All fans should be cleaned regularly by removing accumulated dirt and debris on louvers, blades and motors to improve performance. Dirt that clogs your fan motor will cause it to run hot, and will reduce the life of your motor. You should also regularly check fan belts and keep them adjusted to factory specifications. Loose belts can cause belt slippage and will reduce the airflow of your fan.
J&D recommends a cooling system when temperatures reach between 85° – 90° depending on your application.
In the summer, a ceiling fan creates a mild wind chill to help cool the building. In the winter, a ceiling fan helps to mix the warm air that collects on the ceiling and in the peaks of most industrial and commercial buildings. By installing a ceiling fan, the warm air is recirculated back down to the floor level to help maintain a uniform temperature and save on heating costs.
For preventing heat stratification, it will be depend on the height of the ceiling. With ceilings between 15′ and 30′, ceiling fans should be mounted to cover 4000 square feet of floor area. For cooling people during the hot summer months, fans should be placed 15′ to 20′ apart.
J&D recommends having all electrical work performed by a certified electrician. The electrician can find the wiring diagram on the motor label.
J&D offers a 2 year replacement warranty on all electric fan motors, unlike many of our competitors who offer only a one year warranty. Warranty is based on invoice date to the dealer, J&D does not cover freight or labor. POW14, POW18, POW18B, POW24OSC, POW30OSC, VBM60PSC-P, VBM148PSC-P, PDF24, and VRSM10-Power inlet motor carry a 1 year warranty. VR3E and VR33 motors (Mega Storm Fan) carry a 3 year warranty.