Back To Categories

Poly Chiller

Product Description:
The Poly Chiller™ from J&D Manufacturing is an efficient air circulator with gold medal performance. The heavy-duty motor mount is connected directly to the multi-positional hanging bracket, meaning the poly housing is not part of the support structure and will not distort like other poly fans.

INTERESTED IN THIS PRODUCT?

Fill out the form and we will be in touch within a business day!

  • Have a question about this product?
  • Complete the form below and we'll be in touch with you soon.

READY TO PURCHASE?

Find a Dealer

Key Features:

  • Available in 24” and 36”
  • One-piece molded black polyethylene housing WILL NOT RUST!
  • Fan ships completely assembled and ready for installation
  • 3-blade galvanized or aluminum prop
  • Enhance cooling power with high pressure fog attachment
  • Direct drive motor with no belts or bearings to maintain
  • Heavy-duty, corrosion-resistant powder coated brackets, motor mount, and guards
  • Multi-position mounting bracket lets you tilt and lock the fan in place
  • No electrician needed!
    • Just hang it up and plug it in!
  • Round housing shape is easy to clean with no corners for dirt build-up

Applications:

  • Dairy
  • Greenhouse
  • Industrial
  • Poultry
  • Swine
Part # Motor Wiring Instructions Size Output (CFM) HP Volts Amps NP Hz Ph Spd RPM Drive Prop Test # Cord Speed Control Compatible VFD Compatible Fixed or Portable Oscillating FPM Thrust CFM Thrust (lbf) Thrust Eff. Ratio kW Thrust CFM/ Watt
Part - Motor Wiring Instructions Size Output (CFM) HP Volts Amps NP Hz Ph Spd RPM Drive Prop Test # Cord Speed Control Compatible VFD Compatible Fixed or Portable Oscillating FPM Thrust CFM Thrust (lbf) Thrust Eff. Ratio kW Thrust CFM/ Watt
Single Phase Without Cord
VPRF24 --- 24” 4890 1/2 115/230 4.8/2.4 60 1 1 1,730 Direct 3-Alm C08024 No N N Fixed Non 890 4,890 4.7 10.5 0.45 10.9
VPRF36 --- 36” 10120 1/2 115/230 6.1/3.09 60 1 1 832 Direct 3-Glv C19342 No No No Fixed Non 720 9,750 8.3 14.7 0.56 17.4
1 PH With Cord Wired for 115V
VPRF24-C115 --- 24” 4890 1/2 115 4.8/2.4 60 1 1 1,730 Direct 3-Alm C08024 Yes N N Fixed Non 890 4,890 4.7 10.5 0.45 10.9
VPRF36-C115 --- 36” 9390 1/2 115 6.1/3.09 60 1 1 833 Direct 3-Glv C19343 Yes No No Fixed Non 750 9,390 7.7 14.2 0.54 17.4
1 PH With Cord Wired for 230V
VPRF24-C230 --- 24” 4890 1/2 230 4.8/2.4 60 1 1 1,730 Direct 3-Alm C08024 Yes No No Fixed Non 890 4,890 4.7 10.5 0.45 10.9
VPRF36-C230 --- 36” 9750 1/2 230 6.1/3.09 60 1 1 832 Direct 3-Glv C19342 Yes No No Fixed Non 720 9,750 8.3 14.7 0.56 17.4
Three Phase Without Cord
VPRF243 --- 24” 5240 1/2 230/460 2.6/1.3 60 3 1 857 Direct 3-Glv C21010 No N N Fixed Non 630 5,110 5.3 11.7 0.46 11.2
VPRF363 --- 36” 9770 1/2 230/460 2.6/1.3 60 3 1 846 Direct 3-Glv C21011 No N N Fixed Non 730 9,680 8.5 15.4 0.55 17.5
Part #
VPRF24
Single Phase Without Cord
Details
Poly Chiller, 24" DD 115/230V 1/2HP 1PH S/Var, w/Brkt
Motor Wiring Instructions
---
Size
24”
Output (CFM)
4890
HP
1/2
Volts
115/230
Amps NP
4.8/2.4
Hz
60
Ph
1
Spd
1
RPM
1,730
Drive
Direct
Prop
3-Alm
Test #
C08024
Cord
No
Speed Control Compatible
N
VFD Compatible
N
Fixed or Portable
Fixed
Oscillating
Non
FPM
890
Thrust CFM
4,890
Thrust (lbf)
4.7
Thrust Eff. Ratio
10.5
kW
0.45
Thrust CFM/ Watt
10.9
Part #
VPRF36
Single Phase Without Cord
Details
Poly Chiller, 36" DD 115/230V 1/2HP 1PH 1SP, w/Brkt
Motor Wiring Instructions
---
Size
36”
Output (CFM)
10120
HP
1/2
Volts
115/230
Amps NP
6.1/3.09
Hz
60
Ph
1
Spd
1
RPM
832
Drive
Direct
Prop
3-Glv
Test #
C19342
Cord
No
Speed Control Compatible
No
VFD Compatible
No
Fixed or Portable
Fixed
Oscillating
Non
FPM
720
Thrust CFM
9,750
Thrust (lbf)
8.3
Thrust Eff. Ratio
14.7
kW
0.56
Thrust CFM/ Watt
17.4
Part #
VPRF24-C115
1 PH With Cord Wired for 115V
Details
Poly Chiller, 24" DD 115V 1/2HP 1PH S/Var, w/Brkt, 10' Cord
Motor Wiring Instructions
---
Size
24”
Output (CFM)
4890
HP
1/2
Volts
115
Amps NP
4.8/2.4
Hz
60
Ph
1
Spd
1
RPM
1,730
Drive
Direct
Prop
3-Alm
Test #
C08024
Cord
Yes
Speed Control Compatible
N
VFD Compatible
N
Fixed or Portable
Fixed
Oscillating
Non
FPM
890
Thrust CFM
4,890
Thrust (lbf)
4.7
Thrust Eff. Ratio
10.5
kW
0.45
Thrust CFM/ Watt
10.9
Part #
VPRF36-C115
1 PH With Cord Wired for 115V
Details
Poly Chiller, 36" DD 115V 1/2HP 1PH 1SP, w/Brkt, 10' Cord
Motor Wiring Instructions
---
Size
36”
Output (CFM)
9390
HP
1/2
Volts
115
Amps NP
6.1/3.09
Hz
60
Ph
1
Spd
1
RPM
833
Drive
Direct
Prop
3-Glv
Test #
C19343
Cord
Yes
Speed Control Compatible
No
VFD Compatible
No
Fixed or Portable
Fixed
Oscillating
Non
FPM
750
Thrust CFM
9,390
Thrust (lbf)
7.7
Thrust Eff. Ratio
14.2
kW
0.54
Thrust CFM/ Watt
17.4
Part #
VPRF24-C230
1 PH With Cord Wired for 230V
Details
Poly Chiller, 24" DD 230V 1/2HP 1PH, w/Brkt, 10' Cord
Motor Wiring Instructions
---
Size
24”
Output (CFM)
4890
HP
1/2
Volts
230
Amps NP
4.8/2.4
Hz
60
Ph
1
Spd
1
RPM
1,730
Drive
Direct
Prop
3-Alm
Test #
C08024
Cord
Yes
Speed Control Compatible
No
VFD Compatible
No
Fixed or Portable
Fixed
Oscillating
Non
FPM
890
Thrust CFM
4,890
Thrust (lbf)
4.7
Thrust Eff. Ratio
10.5
kW
0.45
Thrust CFM/ Watt
10.9
Part #
VPRF36-C230
1 PH With Cord Wired for 230V
Details
Poly Chiller, 36" DD 230V 1/2HP 1PH 1SP, w/Brkt, 6' Cord
Motor Wiring Instructions
---
Size
36”
Output (CFM)
9750
HP
1/2
Volts
230
Amps NP
6.1/3.09
Hz
60
Ph
1
Spd
1
RPM
832
Drive
Direct
Prop
3-Glv
Test #
C19342
Cord
Yes
Speed Control Compatible
No
VFD Compatible
No
Fixed or Portable
Fixed
Oscillating
Non
FPM
720
Thrust CFM
9,750
Thrust (lbf)
8.3
Thrust Eff. Ratio
14.7
kW
0.56
Thrust CFM/ Watt
17.4
Part #
VPRF243
Three Phase Without Cord
Details
Poly Chiller, 24" DD 1/2HP 230/460V 3PH 1SP, w/Brkt
Motor Wiring Instructions
---
Size
24”
Output (CFM)
5240
HP
1/2
Volts
230/460
Amps NP
2.6/1.3
Hz
60
Ph
3
Spd
1
RPM
857
Drive
Direct
Prop
3-Glv
Test #
C21010
Cord
No
Speed Control Compatible
N
VFD Compatible
N
Fixed or Portable
Fixed
Oscillating
Non
FPM
630
Thrust CFM
5,110
Thrust (lbf)
5.3
Thrust Eff. Ratio
11.7
kW
0.46
Thrust CFM/ Watt
11.2
Part #
VPRF363
Three Phase Without Cord
Details
Poly Chiller, 36" DD 230/460V 1/2HP 3PH 1SP, w/Brkt
Motor Wiring Instructions
---
Size
36”
Output (CFM)
9770
HP
1/2
Volts
230/460
Amps NP
2.6/1.3
Hz
60
Ph
3
Spd
1
RPM
846
Drive
Direct
Prop
3-Glv
Test #
C21011
Cord
No
Speed Control Compatible
N
VFD Compatible
N
Fixed or Portable
Fixed
Oscillating
Non
FPM
730
Thrust CFM
9,680
Thrust (lbf)
8.5
Thrust Eff. Ratio
15.4
kW
0.55
Thrust CFM/ Watt
17.5

Product Details:

Part #

Motor Wiring Instructions

Size

HP

Volts

Amps NP

Hz

Phase

Speed

RPM

Drive

Prop

Test #

Speed Control Compatibility

VFD Compatible

Fixed or Portable

FPM

Thrust CFM

Thrust (lbf)

Thrust Eff. Ratio

kW

Thrust CFM/ Watt

Single Phase Without Cord

VPRF24

---

24”

1/2

115/230

4.8/2.4

60

1

1

1,730

Direct

3-Alm

C08024

N

N

Fixed

890

4.7

10.5

0.45

10.9

Single Phase Without Cord

VPRF36

---

36”

1/2

115/230

6.1/3.09

60

1

1

832

Direct

3-Glv

C19342

No

No

Fixed

720

8.3

14.7

0.56

17.4

1 PH With Cord Wired for 115V

VPRF24-C115

---

24”

1/2

115

4.8/2.4

60

1

1

1,730

Direct

3-Alm

C08024

N

N

Fixed

890

4.7

10.5

0.45

10.9

1 PH With Cord Wired for 115V

VPRF36-C115

---

36”

1/2

115

6.1/3.09

60

1

1

833

Direct

3-Glv

C19343

No

No

Fixed

750

7.7

14.2

0.54

17.4

1 PH With Cord Wired for 230V

VPRF24-C230

---

24”

1/2

230

4.8/2.4

60

1

1

1,730

Direct

3-Alm

C08024

No

No

Fixed

890

4.7

10.5

0.45

10.9

1 PH With Cord Wired for 230V

VPRF36-C230

---

36”

1/2

230

6.1/3.09

60

1

1

832

Direct

3-Glv

C19342

No

No

Fixed

720

8.3

14.7

0.56

17.4

Three Phase Without Cord

VPRF243

---

24”

1/2

230/460

2.6/1.3

60

3

1

857

Direct

3-Glv

C21010

N

N

Fixed

630

5.3

11.7

0.46

11.2

Three Phase Without Cord

VPRF363

---

36”

1/2

230/460

2.6/1.3

60

3

1

846

Direct

3-Glv

C21011

N

N

Fixed

730

8.5

15.4

0.55

17.5

Product Details:

Part #

Motor Wiring Instructions

Size

HP

Volts

Amps NP

Hz

Phase

Speed

RPM

Drive

Prop

Test #

Speed Control Compatibility

VFD Compatible

Fixed or Portable

FPM

Thrust CFM

Thrust (lbf)

Thrust Eff. Ratio

kW

Thrust CFM/ Watt

Housing Material

Housing Color

Guard material & coating

Guard Color

Blade Material

Blade Color

Single Phase Without Cord

VPRF24

---

24”

1/2

115/230

4.8/2.4

60

1

1

1,730

Direct

3-Alm

C08024

N

N

Fixed

890

4,890

4.7

10.5

0.45

10.9

Poly

Black

Black

Aluminum

Metallic

Single Phase Without Cord

VPRF36

---

36”

1/2

115/230

6.1/3.09

60

1

1

832

Direct

3-Glv

C19342

No

No

Fixed

720

9,750

8.3

14.7

0.56

17.4

Poly

Black

Black

Galvanized

Metallic

1 PH With Cord Wired for 115V

VPRF24-C115

---

24”

1/2

115

4.8/2.4

60

1

1

1,730

Direct

3-Alm

C08024

N

N

Fixed

890

4,890

4.7

10.5

0.45

10.9

Poly

Black

Black

Aluminum

Metallic

1 PH With Cord Wired for 115V

VPRF36-C115

---

36”

1/2

115

6.1/3.09

60

1

1

833

Direct

3-Glv

C19343

No

No

Fixed

750

9,390

7.7

14.2

0.54

17.4

Poly

Black

Black

Galvanized

Metallic

1 PH With Cord Wired for 230V

VPRF24-C230

---

24”

1/2

230

4.8/2.4

60

1

1

1,730

Direct

3-Alm

C08024

No

No

Fixed

890

4,890

4.7

10.5

0.45

10.9

Poly

Black

Black

Aluminum

Metallic

1 PH With Cord Wired for 230V

VPRF36-C230

---

36”

1/2

230

6.1/3.09

60

1

1

832

Direct

3-Glv

C19342

No

No

Fixed

720

9,750

8.3

14.7

0.56

17.4

Poly

Black

Black

Galvanized

Metallic

Three Phase Without Cord

VPRF243

---

24”

1/2

230/460

2.6/1.3

60

3

1

857

Direct

3-Glv

C21010

N

N

Fixed

630

5,110

5.3

11.7

0.46

11.2

Poly

Black

Black

Galvanzied

Metallic

Three Phase Without Cord

VPRF363

---

36”

1/2

230/460

2.6/1.3

60

3

1

846

Direct

3-Glv

C21011

N

N

Fixed

730

9,680

8.5

15.4

0.55

17.5

Poly

Black

Black

Galvanized

Metallic

Accessories:

Part # Details
Optional Poly Chiller Brackets
VRSBRD36B Bracket, Poly Chiller, Wall or Post Mount, Bolt On, Black PC
VRSBRD36C Bracket, Poly Chiller, 4-1/2" Column Mount, Black PC
VRSBRD36SQ Bracket, Poly Chiller, Square Post Mount Up to 3", Black PC

FAQs:

Ventilation helps to maintain a healthy environment by regulating moisture and humidity, controlling temperatures, removing fumes and odors, and exchanging fresh air for humans and animals to maximize productivity.
Heat stress in animals is a very serious condition that can lead to a decrease in appetite, loss of milk or egg production, shutdown of the reproduction system, diminished nutrient absorption, poor growth and even death in extreme cases.
There are many important factors to consider when purchasing a fan. Besides cost, you should also consider the efficiency of the fan, the noise level, and the energy use. Many ventilation fans have a lower upfront price tag, but will cost you more over time by consuming large amounts of energy.
J&D has numerous options for your dairy ventilation system including natural, recirculation, tunnel, and cross-tunnel ventilation. In addition to these basic ventilation types, evaporative pad cooling, soaking, misting, fogging and mechanical ventilation can all be intermixed to maximize the cooling capacity of your system.
A Natural Ventilation System relies only on wind to cool your barn using open side walls or curtain side walls.

Advantages: low investment cost, low electrical operating cost, zero fan noise, easy management and operation, bright and airy work space, animals will not be affected by power failures.

Disadvantages: little to no temperature and air exchange control, no insect control, radiant sun increases temperature on outside stalls, precise building location is required to maximize wind direction.
A Tunnel Ventilation System uses a series of exhaust fans on the short end of your building with inlets located on the opposite end. Air enters the building through the inlets where it is pulled down the length of your building like a wind tunnel and exhausted out the opposite end. The exhaust fans create air exchange and a high velocity air movement.

Advantages: insect control, consistent environment, proper temperature, humidity and odor control, keeps bedding and floors dry.

Disadvantages: higher investment cost when compared to natural ventilation, very little natural light, not suitable for year round use without a fresh air system due to inadequate fresh air distribution during cool winter ventilation conditions.
Cross Tunnel Ventilation is very similar to Tunnel Ventilation whereas a series of exhaust fans and inlets are used on the walls of your building. With Cross Tunnel Ventilation, the exhaust fans and inlets are located on the long sides of your building instead of the short sides. The air is pulled through the width of your building instead of through the length like it is with regular Tunnel Ventilation.

Advantages: building ends can be used for necessary overhead doors, insect control, consistent environment, proper temperature, humidity and odor control, keeps bedding and floors dry.

Disadvantages: higher investment cost when compared to natural ventilation, very little natural light, not suitable for year round use due to inadequate fresh air distribution during cool winter ventilation conditions.
Recirculation Ventilation uses a series of recirculation fans that are positioned to blow air across the animals to create a cooling effect. When designed properly with an open or curtain side wall, you can also get an air exchange in the building.

Advantages: insect control, consistent environment, proper temperature, humidity and odor control, keeps bedding and floors dry

Disadvantages: higher installation and operating costs when compared to natural ventilation.
Selecting a ventilation system depends on a number of factors including budget, building location and orientation, and your complete ventilation strategy. Call our ventilation experts at 1-800-998-2398 or e-mail us at jdmfg@jdmfg.com to help design the best system for you.
J&D has knowledgable Engineering and Sales staff that can assist you in this process. We will design and recommend options to give you the most effective system. Call our ventilation experts at 1-800-998-2398 or e-mail us at jdmfg@jdmfg.com to help design the best system for you.
All fans should be cleaned regularly by removing accumulated dirt and debris on louvers, blades and motors to improve performance. Dirt that clogs your fan motor will cause it to run hot, and will reduce the life of your motor. You should also regularly check fan belts and keep them adjusted to factory specifications. Loose belts can cause belt slippage and will reduce the airflow of your fan.
J&D recommends a cooling system when temperatures reach between 85° – 90° depending on your application.
In the summer, a ceiling fan creates a mild wind chill to help cool the building. In the winter, a ceiling fan helps to mix the warm air that collects on the ceiling and in the peaks of most industrial and commercial buildings. By installing a ceiling fan, the warm air is recirculated back down to the floor level to help maintain a uniform temperature and save on heating costs.
For preventing heat stratification, it will be depend on the height of the ceiling. With ceilings between 15′ and 30′, ceiling fans should be mounted to cover 4000 square feet of floor area. For cooling people during the hot summer months, fans should be placed 15′ to 20′ apart.
J&D recommends having all electrical work performed by a certified electrician. The electrician can find the wiring diagram on the motor label.
J&D offers a 2 year replacement warranty on all electric fan motors, unlike many of our competitors who offer only a one year warranty. Warranty is based on invoice date to the dealer, J&D does not cover freight or labor. POW14, POW18, POW18B, POW24OSC, POW30OSC, VBM60PSC-P, VBM148PSC-P, PDF24, and VRSM10-Power inlet motor carry a 1 year warranty. VR3E and VR33 motors (Mega Storm Fan) carry a 3 year warranty.